AXIOM
CONTROLLER
GND
TACH-
TACH+
V+
GND
V+
TRIG+
TRIG-
GND
TX1
TX2
RX1
RX2
TX+
TX-
RX+
RX-
V+
GND
POWER
I/01+
I/01-
I/02+
I/02-
RELAYS 1 & 2
I/03+
I/03-
I/04+
I/04-
RELAYS 3 & 4
V+
GND
POWER
ETHERNET
TACH
TRIGGER
SERIAL COM
GRN/WH
ORG
ORG/WH
GRN
AXIOM
40 WATT POWER SUPPLY
V+
GND
POWER
I/01+
I/01-
I/02+
I/02-
RELAYS 1 & 2
I/03+
I/03-
I/04+
I/04-
RELAYS 3 & 4
V+
GND
POWER
ETHERNET
TX+
TX-
RX+
RX-
TACH
V+
TACH+
TACH-
GND
TRIGGER
TRIG+
V+
GND
TRIG-
SERIAL COM
TX1
TX2
RX1
RX2
GND
AXIOM
CLIENT1
AXIOM
40 WATT POWER SUPPLY
RED OR WHITE
BLK
ORG
ORG/WH
GRN
GRN/WH
BLK
RED OR WHITE
AXIOM
40 WATT POWER SUPPLY
GRN/WH
GRN
ORG/WH
ORG
RED OR WHITE
BLK
AXIOM
CLIENT 2
GND
V+
GND
POWER
I/01+
I/01-
I/02+
I/02-
RELAYS 1 & 2
I/03+
I/03-
I/04+
I/04-
RELAYS 3 & 4
GND
POWER
SERIAL COM
TRIGGER
TACH
ETHERNET
V+
V+
TACH+
TACH-
GND
V+
TRIG+
TRIG-
GND
TX1
TX2
RX1
RX2
TX+
TX-
RX+
RX-
PORT5
PORT4
PORT3
PORT2
PORT1
LINKSYS
5-PORT
ETHERNET SWITCH
AXIOM DIAGNOSTIC AND
CONFIGURATION PC
RUNNING AXCESS
HOST PC
TACHOMETER
NOTE: TACH MUST BE
SET FOR NPN OPEN
COLLECTOR
PHOTO EYE
HOST RS232 PORT GND
HOST RS232 PORT RECEIVE
HOST RS232 PORT TRANSMIT
BLK
WHT
RED
BLK
WHT
RED
NOTE:
MAX. 5 AXIOM
CLIENTS PER
CONTROLLER
AXIOM
CLIENT 5
GREEN
GREEN
GREEN
N/A
N/A
N/A
A
B
C
D
B
4
3
1
2
4
C
CONTROLLER/CLIENT/CLIENT W/TACH, AXIOM
INTERCONNECT DRAWING,
R
107481
DWG. NO.
53830
CAGE CODE
1 OF 1
SOLIDWORKS
NONE
CAD SYS.
DATE
B
SIZE
DATE
DATE
MECH ENG
11.06.04
11.06.04
11.06.04
DRAWN
CHKD
ENGR
DEPT.
CUSTOMER
TCS
RAD
RAD
E-
SCALE
CONTRACT #
TELFORD, PA 18969 USA
ACCU-SORT SYSTEMS, inc.
D
C
A
1
2
3
PART NO. 0107481000
SHEET
REMOVE SHARP EDGES AND BURRS
THIS IS NOT A CONTROLLED COPY UNLESS
STAMPED “CONTROLLED COPY” IN RED
THIS DOCUMENT IS PROVIDED FOR A
SPECIFIC PURPOSE AND THE DISCLOSED
INFORMATION REMAINS OUR PROPERTY.
IT MAY NOT BE DISCLOSED, COPIED,
OR REPRODUCED, EXCEPT FOR THE
SPECIFIC PURPOSE, WITHOUT ACCU-SORT’S
PRIOR APPROVAL. THIS NOTICE MUST
APPEAR ON ANY COPY OR REPRODUCTION
OF THIS DOCUMENT.
2004 ACCU-SORT SYSTEMS, INC.
FT.,IN ±1"
FRACTIONS ±1/4
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES [MILLIMETERS]
ALL ANGLES ARE 90°
ALL C-CINKS ARE 82° INCLUDED ANGLE
ALL BEND RELIEFS TO SUIT
TOLERANCES:
INCH
.X±.1000
.XX±.0200
.XXX±.0050
.XXXX±.0005
[METRIC]
[X±2.500]
[.X±0.500]
[.XX±0.130]
[.XXX±0.013]
ANGULAR
X±1.00°
.X±0.10°
.XX±0.01°
REVISION
BY
AS
ECO
DATE
05/14/09
09-214
REV
05
NOTES:
1. TACHOMETER MUST BE CONFIGURED FOR NPN OPEN COLLECTOR OUTPUT.
2. TO KEEP DRAWING SIMPLER, CABLE SHIELDS ARE NOT SHOWN.
APPLICATION EXAMPLE:
THREE UNIT CONTROLLER/CLIENT TRACKING
CONFIGURATION. THIS CONFIGURATION COULD BE
A X PATTERN TOP READ WITH A SINGLE FRONT READ
AXIOM. SERIAL PORT FROM CONTROLLER AXIOM
WILL TRANSMIT DATA FROM READ STATION TO
A SORTATION CONTROLLER. HOST PC ATTACHED TO
ETHERNET SWITCH COULD BE USED FOR DATA
COLLECTION. AXIOM DIAGNOSTIC AND CONFIGURATION
PC CAN BE USED TO MONITOR PERFORMANCE OF
INDIVIDUAL AXIOM SCANNERS IN READ STATION.
ALL 3 SCANNERS COULD BE MONITORED BY OPENING
3 INSTANCES OF ACCESS AND ATTACHING TO
THE IP ADDRESSES OF THE INDIVIDUAL SCANNERS
IN THE READ STATION.
Summary of Contents for AXIOM
Page 1: ...AXIOM AXIOM X Laser Bar Code Scanning Solutions Product Line Manual ...
Page 223: ......
Page 224: ......