General Mounting Guidelines
As you plan the installation for your application, keep the following in mind:
Determine the proper orientation and position of the reader.
Allow approximately 8-12 inches [203-305 mm] of clearance.
Plan mechanical installation based on the application’s electrical
requirements.
See General Electrical Installation Guidelines, Chapter 4.
Follow all safety precautions when installing, setting up, operating,
maintaining, troubleshooting or replacing any Accu-Sort products, parts
or related equipment.
See Chapter 2, Safety.
Reader Positioning
IMPORTANT:
The AXIOM readers are able to decode bar codes at a
variety of angles; however significant angular distortion may degrade
reading performance. When positioning a reader, be aware of how the
scanning beam exits the scan window in relation to the wiring base.
When mounting the AXIOM readers, take into consideration:
The bar code orientation
The reader’s scanning beam must intersect entire bar code
Range of motion allowed by the Universal Mounting Bracket (UMB)
AXIOM Range of Motion with UMB
AXIOM-X Range of Motion with UMB
Yaw +/- 22.5
˚
Roll 360
˚
Range of motion when unobstructed with power supply.
Downward travel is limited to 105
˚
. Other obstructions may limit travel.
Pitch 50
˚
up (max) 130
˚
down (max)
When on an Accu-Sort mounting structure, re-positioning of mounting bolts may be required.