AXIOM
HOST RS232 PORT GND
HOST RS232 PORT RECEIVE
HOST RS232 PORT TRANSMIT
BLK
WHT
RED
GND
RX2
RX1
TX2
TX1
GND
TRIG-
TRIG+
V+
GND
TACH-
TACH+
V+
RX-
RX+
TX-
TX+
V+
GND
I/01+
I/01-
I/02+
I/02-
I/03+
I/04-
I/04+
I/03-
GND
V+
ETHERNET
SERIAL COM
TRIGGER
TACH
POWER
RELAYS 1 & 2
RELAYS 3 & 4
POWER
RED
BLK
START TRIGGER PHOTOEYE
CUSTOMER SUPPLIED 24 VDC
c
2
1
4
3
6
5
STACKLIGHT STANDARD BASE
RED STACKLIGHT
DC OUTPUT MODULE
I/O 4
I/O 3
I/O 2
I/O 1
PHOTO EYE
DC OUTPUT MODULE
DC OUTPUT MODULE
GREEN STACKLIGHT
YELLOW STACKLIGHT
PE GROUND
GREEN/YELLOW
N/A
N/A
N/A
A
B
C
D
B
4
3
1
2
4
C
STACK LAMP W/INTERNAL RELAYS,AXIOM
INTERCONNECT DRAWING,
R
107483
DWG. NO.
53830
CAGE CODE
1 OF 1
SOLIDWORKS
NONE
CAD SYS.
DATE
B
SIZE
DATE
DATE
MECH ENG
11.07.04
11.07.04
11.07.04
DRAWN
CHKD
ENGR
DEPT.
CUSTOMER
TCS
RAD
RAD
E-
SCALE
CONTRACT #
TELFORD, PA 18969 USA
ACCU-SORT SYSTEMS, inc.
D
C
A
1
2
3
PART NO. 0107483000
SHEET
REMOVE SHARP EDGES AND BURRS
THIS IS NOT A CONTROLLED COPY UNLESS
STAMPED “CONTROLLED COPY” IN RED
THIS DOCUMENT IS PROVIDED FOR A
SPECIFIC PURPOSE AND THE DISCLOSED
INFORMATION REMAINS OUR PROPERTY.
IT MAY NOT BE DISCLOSED, COPIED,
OR REPRODUCED, EXCEPT FOR THE
SPECIFIC PURPOSE, WITHOUT ACCU-SORT’S
PRIOR APPROVAL. THIS NOTICE MUST
APPEAR ON ANY COPY OR REPRODUCTION
OF THIS DOCUMENT.
2004 ACCU-SORT SYSTEMS, INC.
FT.,IN ±1"
FRACTIONS ±1/4
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES [MILLIMETERS]
ALL ANGLES ARE 90°
ALL C-CINKS ARE 82° INCLUDED ANGLE
ALL BEND RELIEFS TO SUIT
TOLERANCES:
INCH
.X±.1000
.XX±.0200
.XXX±.0050
.XXXX±.0005
[METRIC]
[X±2.500]
[.X±0.500]
[.XX±0.130]
[.XXX±0.013]
ANGULAR
X±1.00°
.X±0.10°
.XX±0.01°
REVISION
BY
AS
ECO
DATE
05/20/09
09-214
REV
04
NOTES:
1. TO KEEP DRAWING SIMPLER, CABLE SHIELDS ARE NOT SHOWN
2. IF ASI POWER SUPPLY PART NUMBER 105365001 IS USED ONLY 1 LAMP CAN BE ILLUMINATED
3. CUTLER-HAMMER EXTENSION TUBE # E26BJU AND A 3/4 " NPT FEMALE TO 1/2” NPT MALE
ADAPTER CAN BE USED TO MOUNT THE STACK LIGHT DIRECTLY TO THE WIRING BASE OF THE AXIOM.
4. CURRENT DRAW OF EACH LAMP IS 250mA.
APPLICATION EXAMPLE:
WIRING SHOWN IS TYPICAL OF APPLICATION REQUIRING 3
INDICATOR LAMPS. LAMPS ARE POWERED BY SAME 24 VDC
SUPPLY THAT POWERS THE SCANNER. SERIAL PORT FROM
AXIOM WILL TRANSMIT DATA TO SORTATION CONTROLLER.
AXIOM SCANNERS ARE CONFIGURED BY ATTACHING
SERIALLY TO THE SET UP PORT ON THE WIRING BASE.
Summary of Contents for AXIOM
Page 1: ...AXIOM AXIOM X Laser Bar Code Scanning Solutions Product Line Manual ...
Page 223: ......
Page 224: ......
Page 225: ......