192
34
Humidifying element
reception
40. to 44.
<VNK type only>
44. Turn the cord clip to remove the sensor assembly
2.
Remove the two tapping screws (M4 × 10) that fix
the humidifying element reception, and lift it up then
pull it toward you. Use pliers or the like to pinch the
back of the sensor assembly 2 and cord clip, and
then remove them.
35
Sensor attachment
metal fittings
40., 45.
<VNK type only>
45. Turn the cord clip to remove the sensor assembly
2.
Remove the two tapping screws (M4 × 10) that fix
the sensor attachment metal fittings, and lift them
up then pull them toward you.
Use pliers or the like to pinch the back of the sensor
assembly 2 and cord clip, and then remove them.
36
Supply water
hose 1, 2
40. to 42., 46.
<VNK type only>
46. Slide the hose band to remove the supply water
hoses 1 and 2.
No.
Component
Procedure
Note
Humidifying element
reception
Cord clip
Tapping screws
(M4 × 10)
Sensor
assembly 2
Sensor attachment metal fittings
Tapping screws (M4 × 10)
Sensor
assembly 2
Cord clip
Supply water branch
Supply water
hose 2
Hose band
Supply water
hose 1