195
45
Separation board
40., 41., 48., 49., 54.,
55.
55. Use pliers or the like to push inward the sensor
assembly 1 fixed on the separation board.
Remove the three truss head tapping screws (M4 ×
10) that fix the separation board.
Push the lower part of the separation board deep to
pull it toward you.
46
Guide water
40., 41., 48., 49.,
54. to 56.
56. Remove the truss head tapping screw (M4 × 10)
that fixes the guide water.
Pull the guide water up and then toward you.
47
Supply water pipe
assembly
40., 41., 48., 49., 54.,
55., 57.
<VNK type only>
57. Use a spanner (17) to loosen the flare nut that fixes
the supply water pipe assembly to remove the
assembly.
48
Quick fastener
40., 41., 48., 49., 58.
<VNK type only>
58. Pull down the quick fastener in the direction against
the opening to remove the quick fastener.
No.
Component
Procedure
Note
Sensor assembly 1
Tapping screws (M4 × 10)
Tapping screws (M4 × 10) Guide water
Flair nut
Opening
Quick
fastener