156
Installation Manual
Connection diagram
1. The dotted line represents a wire procured locally, and the dashed line represents an option sold separately.
2.
represents a terminal block,
represents a connection terminal,
represents a connector on the
printed circuit board and
represents a short circuit connector.
3.
represents a protective earth.
4.
represents a printed circuit board.
5. Using a no voltage a-contact input of the external input (sold separately), the following operations are available:
Between 1 and 2: Selecting the remote controller operation (Invalid / Valid)
Between 1 and 3: Adjusting the fan speed (Low / High)
Between 1 and 5: Operation (ON/OFF)
Use a microcurrent contact (DC12 V, 1 mA). In addition, ON/OFF operation is possible when using a voltage of
DC12 V or 24 V.
6. Orange wire (High) is connected as factory default. To switch to “Extra High”, connect black wire’s connector
instead of orange.
7. The unit cannot run when the temperature of the outdoor air is below -15 °C.
Power supply for
indoor unit
220-240 V~, 50 Hz
220 V~, 60 Hz
Earth
represents the connector to switch
between Extra High and High.
Wiring between indoor
and outdoor unit
Wiring for
the remote
controller
Wired remote controller
(sold separately)
Indoor control
circuit board
MCC1615
Connector
(White)
Connector
(Black)
External output
(220-240V~, under 1A each)
*5 External input (sold separately)
No voltage a-contact input
Voltage DC (12V, 24V)
input
Operation output
White
Wh
it
e
Red
Connector
(White *6)
Yellow
Connector
(Red *6)
(White)
Red
Red
Re
d
Bl
u
e
Or
an
ge
Re
d
Bl
u
e
Or
an
ge
Wh
ite
Ye
llo
w
Blu
e
Pu
rp
le
Re
d
1 Common
2 Remote controller operation
3 Fan speed
5 Operation
Pink
Power
supply
Bl
ac
k
Bl
ue
F01
T3.15A
250V~
Common
External damper output
Abnormal / Bypass
mode output
Red
Bl
ac
k
Bl
ue
Purple
Pink
Gray
Yellow
Blue
Blue
Yellow
Gray
Yellow
Yellow
Yellow
Bla
ck
Or
ange
Wh
it
e
Wh
it
e
Re
d
Yellow
Yellow
Bl
u
e
Bl
u
e
Bla
ck
Ora
nge
Ora
nge
Oran
ge
Black
(Red)
(White)
(Black)
(Yellow)
(Black)
(Blue)
(Brown)
(Black)
(Red)
(Green)
(Yellow)
(Blue)
(White)
(Blue)
(Blue)
(Red)
(Red)
(Blue)
(Red)
Pink
F02
T15A
250V~
Red
Red
Air to Air Heat
Exchanger with
DX Coil Unit
(VNK type only)
*
1: VNK type only
Code
Parts name
CN***
Connector
F01
Fuse (Printed circuit board)
F02
Fuse (Motor)
FM1
Air supplying motor
FM2
Air exhausting motor
DAM
Damper motor
TRA
TRA sensor
TOA
TOA sensor
TSA
TSA sensor
Code
Parts name
TFA
TFA sensor
TCJ, TC1, TC2
Indoor coil sensor
TB1
Terminal block (power source)
TB2
Terminal block (communication)
TB3
Terminal block (external output)
TB4
*1
Terminal block (Humidistat)
TB5
*1
Terminal block (Magnetic valve)
FS1
Float switch
MV1
*1
Magnetic Valve
Code
Parts name
DMV1
*1
Decompression magnetic valve
PMV
Pluse modulating valve
SW701
DIP switch
43F11, 43F12
Relay for air supplying motor
43F21, 43F22
Relay for air exhausting motor
RY701, RY702
Relay for air supplying motor
RY704, RY705
Relay for exhausting motor
Содержание MD-VNK802HEXE