About air volume imbalance (
[SA>EA] /
[SA<EA])
For normal ventilation (High or Low):
The volumes of the indoor air supply and outdoor air
exhaustion are set to the same level.
For volume ventilation imbalance:
• When
[SA>EA] is selected: the volume of the
indoor air supply is larger than that of the outdoor air
exhaustion.
(Inflow of humidity and smells from the toilet and
kitchen is reduced.)
• When
[SA<EA] is selected: the volume of the
outdoor air exhaustion is larger than that of the
indoor air supply.
(Outflow of smells and floating bacteria into a
corridor or other places is reduced.
* Consult your dealer if the setting of the air volume
imbalance seems incorrect.
Changing ventilation mode
1
Push the
button to select a ventilation
mode.
Each time the button is pushed, the ventilation
mode and indication change as follows:
About ventilation modes
The unit has two ventilation modes.
•
Automatic mode
The heat exchange mode and the bypass mode* are
automatically switched between according to the
operation mode (cooling, heating, dry, ventilation),
setting temperature, or information from the indoor /
outdoor thermo sensor of the Air to Air Heat
Exchanger with DX Coil Unit.
•
Heat exchange mode
Exchanging heat between the outdoor and indoor air
and making the temperature and humidity of the
outdoor air closer to those of the indoor air before
supplying it.
*
Bypass mode (unavailable)
Outdoor air is taken into a room as it is. This mode is
mainly used in spring and summer.
CAUTION
If the outdoor temperature falls to 15 °C or below in
[Automatic mode] the system will automatically start to
run in [Heat exchange mode] regardless of the mode
setting to prevent condensation in the Air to Air Heat
Exchanger with DX Coil Unit.
* The indication of the ventilation mode setting does not
change.
Changing the set temperature
1
Push the “TEMP.
” buttons.
Push
to increase the temperature, and
to
decrease the temperature. (The set temperature
cannot be changed in the fan mode.)
About the separate operation
of the Air to Air Heat
Exchanger with DX Coil Unit
in a system linked with air
conditioners
* The procedure below is not effective in a system
equipped with the Air to Air Heat Exchanger with DX
Coil Unit only.
1
Push the
button while the system is
running.
Only the Air to Air Heat Exchanger with DX Coil
Unit stops and the
indicator turns off.
2
Push the
button while the system is
stopped.
The
indicator lights up and the Air to Air Heat
Exchanger with DX Coil Unit starts running
separately.
NOTE
• Normally, the Air to Air Heat Exchanger with DX Coil
Unit ON/OFF as the air conditioner is ON/OFF when it
is in a system linked with air conditioners.
• If “
” is displayed when the
button is pushed,
change certain settings is necessary to operate the
unit separately. Consult your dealer to change the
settings.
Automatic mode
Heat exchange
mode
Содержание MD-VNK802HEXE
Страница 120: ...118 11Owner s Manual Excerpt ...
Страница 137: ...135 12Installation Manual Excerpt ...