198
56
Hose band
(Supply water branch
side)
40. to 42., 46., 47.,
67.
<VNK type only>
67. Remove the hose band.
57
Hose band
(Decompression
magnetic valve
assembly side)
40., 41., 48., 49., 54.,
55., 57., 61., 68.
<VNK type only>
68. Remove the hose band.
58
Drain hose
40., 41., 48., 49., 54.,
55., 57., 61., 69.
<VNK type only>
69. Remove the drain hose.
* After replacement, confirm that the drain hose does
not come into contact with the float switch of the
decompression magnetic valve assembly.
59
Sensor assembly 1
1., 2., 5., 40., 41., 48.,
49., 54., 55., 70.
70. Remove the sensor assembly 1 connector coming
from the cord bush to the PC board.
Remove the sensor assembly 1 cord from the
electrical box clamp and from the clamp in the main
unit on the back of the electrical box.
No.
Component
Procedure
Note
Hose band
Hose band
Drain hose
Clamp
Sensor assembly 1
(Yellow)
Clamp in the main unit
on the back of the electrical box