Application of the ECAP Module
1943
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Enhanced Capture (eCAP) Module
33.3.4 Example 4 - Time Difference (Delta) Operation Rising and Falling Edge Trigger
In
, the eCAP operating mode is almost the same as in previous section except Capture
events are qualified as either Rising or Falling edge, this now gives both Period and Duty cycle
information: Period1 = T
1
+T
2
, Period2 = T
3
+T
4
, …etc Duty Cycle1 (on-time %) = T
1
/ Period1 x 100%, etc
Duty Cycle1 (off-time %) = T
2
/ Period1 x 100%, etc
During initialization, you must write to the active registers for both period and compare. This will then
automatically copy the init values into the shadow values. For subsequent compare updates, during run-
time, only the shadow registers must be used.
Figure 33-12. Capture Sequence for Delta Mode Time-stamp With Rising and Falling Edge Detect