FlexRay Module Registers
1285
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.1.7 Transfer Base Address (TBA)
The Transfer Base Address register holds a 32-bit aligned 32-bit base-pointer, which defines the base
address for the data to be transferred.
NOTE:
A write to this register also modifies the NTBA register.
Figure 26-39. Transfer Base Address (TBA) [offset_TU = 24h]
31
16
TBA
R/W-0
15
0
TBA
R/W-0
LEGEND: R/W = Read/Write; -
n
= value after reset
Table 26-25. Transfer Base Address (TBA) Field Descriptions
Bit
Field
Description
31-0
TBA
Transfer Base Address. 32-bit base pointer, 2 LSB are not significant (32-bit accesses only) and will
always be 0.
26.3.1.8 Next Transfer Base Address (NTBA)
The Next Transfer Base Address hold a 32-bit aligned 32-bit base-pointer to be loaded into TBA during
next cycle start.
NOTE:
A write on TBA register also modifies the NTBA register.
Figure 26-40. Next Transfer Base Address (NTBA) [offset_TU = 28h]
31
16
NTBA
R/W-0
15
0
NTBA
R/W-0
LEGEND: R/W = Read/Write; -
n
= value after reset
Table 26-26. Next Transfer Base Address (NTBA) Field Descriptions
Bit
Field
Description
31-0
NTBA
Next Transfer Base Address. 32-bit base pointer, 2 LSB are not significant (32-bit accesses only) will