SCI/LIN Control Registers
1672
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Serial Communication Interface (SCI)/ Local Interconnect Network (LIN)
Module
Table 29-12. SCI Global Control Register 1 (SCIGCR1) Field Descriptions (continued)
Bit
Field
Value
Description
0
COMM MODE
SCI/LIN communication mode bit. In compatibility mode it selects the SCI communication mode.
In LIN mode it selects length control option for ID-field bits ID4 and ID5.
SCI mode:
0
Idle-line mode is used.
1
Address-bit mode is used.
LIN mode:
0
ID4 and ID5 are not used for length control.
1
ID4 and ID5 are used for length control.
(1)
The flags are frozen with their reset value while SWnRST = 0.
Table 29-13. SCI Receiver Status Flags
SCI Flag
Register
Bit
Value After Reset
(1)
CE
SCIFLR
29
0
ISFE
SCIFLR
28
0
NRE
SCIFLR
27
0
FE
SCIFLR
26
0
OE
SCIFLR
25
0
PE
SCIFLR
24
0
RXWAKE
SCIFLR
12
0
RXRDY
SCIFLR
9
0
BUSY
SCIFLR
3
0
IDLE
SCIFLR
2
0
WAKE UP
SCIFLR
1
0
BRKDT
SCIFLR
0
0
(1)
The flags are frozen with their reset value while SWnRST = 0.
Table 29-14. SCI Transmitter Status Flags
SCI Flag
Register
Bit
Value After Reset
(1)
BE
SCIFLR
31
0
PBE
SCIFLR
30
0
TX WAKE
SCIFLR
10
0
TX EMPTY
SCIFLR
11
1
TXRDY
SCIFLR
8
1