HWAG Registers
1058
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
High-End Timer (N2HET) Module
23.5.18 HWAG Filter Register (HWAFIL)
Figure 23-106. HWAG Filter Register (HWAFIL)
31
16
Reserved
R-0
15
10
9
0
Reserved
FIL1
R-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 23-70. HWAG Filter Register (HWAFIL) Field Descriptions
Bit
Field
Value
Description
31-10
Reserved
0
Reads return 0. Writes have no effect.
9-0
FIL1
0-3FFh
Filter Value. Contains the value to be compared to the tick counter. It allows the tooth signal
to be taken into account by the HWAG. This function works only if the mode filtering is set.
The value is calculated as shown in
23.5.19 HWAG Filter Register 2 (HWAFIL2)
Figure 23-107. HWAG Filter Register 2 (HWAFIL2)
31
16
Reserved
R-0
15
12
11
0
Reserved
FIL2
R-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 23-71. HWAG Filter Register 2 (HWAFIL2) Field Descriptions
Bit
Field
Value
Description
31-12
Reserved
0
Reads return 0. Writes have no effect.
11-0
FIL2
0-FFFh
Filter Value 2. Contains the value to be compared to the tick counter during the singularity
tooth. It allows the tooth signal to be taken into account by the HWAG. This function works
only if the mode filtering is set. The value is calculated as shown in
.