STC1 Segment 1 (µSCU) Test Coverage and Duration
444
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
Self-Test Controller (STC) Module
10.6 STC1 Segment 1 (µSCU) Test Coverage and Duration
The test coverage and number of test execution cycles (STCCLK) for each test interval are shown in
.
Table 10-4. STC1 Segment 1 Test Coverage and Duration
Intervals
Test Coverage (%)
Test Time (Cycles)
0
0
0
1
84.79
1629
2
87.96
3258
3
88.33
4887
gives the typical STC execution times for 3 intervals at different clock rates. You can choose
the number of intervals to be run based on the coverage needed and allowed time for STC execution.
Table 10-5. Typical Execution Times for STC1 Segment 1
Number of Intervals
Coverage
@ GCLK1 = 330 MHz
STCCLK = 110 MHz
@ GCLK1 = 300 MHz
STCCLK = 100 MHz
3
>88%
44.43 µS
48.87 µS
10.7 STC2 (nHET) Test Coverage and Duration
The test coverage and number of test execution cycles (STCCLK) for each test interval are shown in
.
Table 10-6. STC2 Test Coverage and Duration
Intervals
Test Coverage (%)
Test Time (Cycles)
0
0
0
1
70.01
1365
2
77.89
2730
3
81.73
4095
4
84.11
5460
5
86.05
6825
6
87.78
8190
7
88.96
9555
8
89.95
10920
9
90.63
12285
10
91.20
13650
11
91.60
15015
12
92.02
16380
13
92.37
17745
14
92.66
19110
15
92.87
20475
16
93.04
21840
17
93.26
23205
18
93.47
24570
19
93.67
25935
20
93.82
27300
21
93.96
28665
22
94.12
30030