FlexRay Module Registers
1287
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.1.10 Start Address of Memory Protection (SAMP)
The Start Address of Memory Protection hold a 32-bit address.
Figure 26-42. Start Address of Memory Protection (SAMP) [offset_TU = 30h]
31
16
SAMP
R/W-0
15
0
SAMP
R/W-0
LEGEND: R/W = Read/Write; -
n
= value after reset
Table 26-28. Start Address of Memory Protection (SAMP) Field Descriptions
Bit
Field
Description
31-0
SAMP
Start Address Memory Protection.
Start address of the memory area, which allows read and write accesses for the Transfer Unit State
Machine. 32-bit base pointer, 2 LSB are not significant (32-bit accesses only) will always be 0.
26.3.1.11 End Address of Memory Protection (EAMP)
The End Address of Memory Protection hold a 32-bit address.
Figure 26-43. End Address of Memory Protection (EAMP) [offset_TU = 34h]
31
16
EAMP
R/W-0
15
0
EAMP
R/W-0
LEGEND: R/W = Read/Write; -
n
= value after reset
Table 26-29. End Address of Memory Protection (EAMP) Field Descriptions
Bit
Field
Description
31-0
EAMP
End Address Memory Protection.
End address of the memory area, which allows read and write accesses for the Transfer Unit State
Machine. 32-bit address, 2 LSB are not significant (32-bit accesses only) will always be 0.