NMPU Registers
472
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
System Memory Protection Unit (NMPU)
11.4.1 MPU Revision ID Register (MPUREV)
Figure 11-4. MPU Revision ID Register (MPUREV) [offset = 00h]
31
30
29
28
27
16
SCHEME
Reserved
FUNC
R-1
R-0
R-A0Ch
15
11
10
8
7
6
5
0
RTL
MAJOR
CUSTOM
MINOR
R-0
R-1
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 11-4. MPU Revision ID Register (MPUREV) Field Descriptions
Bit
Field
Value
Description
31-30
SCHEME
1
Identification scheme.
29-28
Reserved
0
Reserved. Reads return 0.
27-16
FUNC
A0Ch
Indicates functionally equivalent module family. This value is dedicated to Hercules family from other
general Texas Instruments MCU or MPU family.
15-11
RTL
0
RTL version number.
10-8
MAJOR
1
Major revision number.
7-6
CUSTOM
0
Indicates device-specific implementation.
5-0
MINOR
0
Minor revision number.
11.4.2 MPU Lock Register (MPULOCK)
Figure 11-5. MPU Lock Register (MPULOCK) [offset = 04h]
31
16
Reserved
R-0
15
4
3
0
Reserved
LOCK
R-0
R/WP-0
LEGEND: R/W = Read/Write; R = Read only; WP = Write in privileged mode only; -
n
= value after reset
Table 11-5. MPU Lock Register (MPULOCK) Field Descriptions
Bit
Field
Value
Description
31-4
Reserved
0
Reserved. Reads return 0.
3-0
LOCK
MPU Register Lock Key. Lock feature prevents unintentional updates to MPU registers. Writes
to registers other than MPUERRSTAT is possible only when MPU is unlocked. This field is
updated only if the write data is 5h or Ah. Register writes are ignored for all other values of write
data.
A built-in correction logic detects single bit soft error on this field and corrects the value in the
next cycle. Functionality and register read data remain the same during the correction cycle.
Read:
Returns current value of LOCK bits.
Write in Privilege:
5h
Writes to other MPU registers are blocked.
Ah
Writes to other MPU registers are allowed.
All other values