FlexRay Module Registers
1397
SPNU563A – March 2018
Copyright © 2018, Texas Instruments Incorporated
FlexRay Module
26.3.2.6.6 New Data Registers (NDAT[1-4])
The four registers reflect the state of the ND flags of all configured message buffers.
ND
flags
corresponding to transmit buffers have no meaning. If the number of configured message buffers is less
than 128, the remaining ND flags have no meaning. The registers are reset when the communication
controller leaves CONFIG state or enters STARTUP state.
through
and
illustrate these registers.
Figure 26-170. New Data Register 4 (NDAT4) [offset_CC = 33Ch]
31
16
ND[127:112]
R-0
15
0
ND[111:96]
R-0
LEGEND: R = Read only; -
n
= value after reset
Figure 26-171. New Data Register 3 (NDAT3) [offset_CC = 338h]
31
16
ND[95:80]
R-0
15
0
ND[79:64]
R-0
LEGEND: R = Read only; -
n
= value after reset
Figure 26-172. New Data Register 2 (NDAT2) [offset_CC = 334h]
31
16
ND[63:48]
R-0
15
0
ND[47:32]
R-0
LEGEND: R = Read only; -
n
= value after reset
Figure 26-173. New Data Register 1 (NDAT1) [offset_CC = 330h]
31
16
ND[31:16]
R-0
15
0
ND[15:0]
R-0
LEGEND: R = Read only; -
n
= value after reset