BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.22
YES
Replace the selector
switch
B
Check whether the input power
supply to the transf ormer is
correct
NO
Replace the
transf ormer and/or the
rectif ier bridge
9
Follow the step-by-step guide to properly diagnose the error. Pay special attention to those tests
indicated in numbered boxes, and described in detail here below:
(1)
Insert the multimeter probes between pins 1 (signal) and 2 of the CN10 connector on the Bio
servo board. You should get a reading of approximately 24 Vdc.
(2)
Insert the multimeter probes between pins 17 (signal) and 1 of the K4 connector on the CPU
board. With the solenoid enabled (additional weight not selected) you should get a reading of
approximately 4 Vdc, while with the solenoid disabled (additional weight selected) you
should get a reading of approximately 0 Vdc.
(3)
Insert the multimeter probes between pins 13 (signal) and 1 of the CN7 connector on the Bio
servo board. With the solenoid enabled (additional weight not selected) you should get a
reading of approximately 4 Vdc, while with the solenoid disabled (additional weight selected)
you should get a reading of approximately 0 Vdc.
On Chest Press and Leg Press, the BS-6/2 cable is divided into 2 parts through the
connector CN36. Carry out the test on this connector and, if necessary, replace only the
defective section of the BS-6/2 cable.
(4)
Insert the multimeter probes between pins 5 (signal) and 6 of the CN3 connector on the Bio
servo board. With the solenoid enabled (additional weight not selected) you should get a
reading of approximately 24 Vdc, while with the solenoid disabled (additional weight
selected) you should get a reading of approximately 0 Vdc.
(5)
Insert the multimeter probes between pins 3 (signal) and 4 of the CN24 patch cord. With the
solenoid enabled (additional weight not selected) you should get a reading of approximately
24 Vdc, while with the solenoid disabled (additional weight selected) you should get a reading
of approximately 0 Vdc.
(6)
Insert the multimeter probes between pins 3 (signal) and 4 of the CN26 patch cord. With the
solenoid enabled (additional weight not selected) you should get a reading of approximately
24 Vdc, while with the solenoid disabled (additional weight selected) you should get a reading
of approximately 0 Vdc.
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......