10.3. MECHANICAL OPERATIONS
These operations must be carried out only by a qualified technician specially trained by
Technogym and authorized to perform machine settings and start-up as well as special
maintenance or repairs requiring in-depth knowledge of the machine, its operation, its
safety features and intervention procedures.
Mechanical operations on the machine involve setting the machine mechanisms to ensure that they
will function properly. We recommend that you carry out these operations
at least once every 1
month
.
Follow the procedure below for mechanical operations:
10.3.1. P
REPARING WORKING CONDITIONS
1. Shut off the machine by setting the switch to 0 (OFF).
2. Unplug the power cord from the wall socket.
3. Open all housings, the Plexiglas weight stack guards and mats on the machine.
10.3.2. C
HECK THE WEIGHT STACK SELECTION SYSTEM
1. Disassemble the weight stack selection system.
2. Check the wear status of the:
•
weight stack selection system chain;
•
selection brush;
•
selection slides.
Repair and/or replace any worn parts.
3. Check the tension of the weight stack selection system chain.
4. Lubricate weight stack selection system chain using FIN FOOD LUBE.
10.3.3. C
HECK THE WEIGHT STACK PLATE SPRINGS
1. Disassemble the weight stack selection system.
2. Check the wear status of the springs on each plate of the weight stack. Repair and/or replace any
worn parts.
CAUTION: do NOT lubricate the springs and/or sliding parts of the plates for any
reason.
3. Clean the plates with dry compressed air.
10.3.4. C
HECK THE CROSS
,
BARS AND WEIGHT STACK PLATES
1. Check the wear status of the cross bushings and weight stack plates. Repair and/or replace any
worn parts.
2. Check the wear status of the weight stack bars and weight stack support buffers. Repair and/or
replace any worn parts.
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......