![Technogym BIOSTRENGTH LINE Скачать руководство пользователя страница 509](http://html1.mh-extra.com/html/technogym/biostrength-line/biostrength-line_service-maintenance-manual_1070169509.webp)
BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.335
7.8.32. D
ISASSEMBLING THE CAM GROUP
Figure 7.8.32-1
Follow the steps described in paragraph 7.8.18.
“Disassembling the upright guard”, 7.8.30.
“Disassembling the weight stack cable”, 7.8.31.
“Disassembling the doubling cable” and 7.8.33.
“Disassembling the levers”.
1. Unscrew the 4 screws
a
(2 on each side)
using a 17-gauge wrench.
2. Remove the CAM GROUP.
To disassemble the components of the CAM
GROUP, place it on a bench or flat surface.
Then:
To disassemble the bearings
b
:
1. Turn the shaft until you can see the 2 dowels
c
, which must be loosened using a 3-gauge
hexagonal T-wrench.
2. Remove the bearing.
To disassemble the hub and cam
d
:
1. Remove the bearings
b
.
2. Unscrew the screw
e
using a 4-gauge
hexagonal T-wrench.
3. Remove the hub and cam.
To separate the cam and hub:
1. Unscrew the 3 screws e using a 6-gauge
hexagonal T-wrench.
2. Separate the components.
To replace the CAM GROUP and its
components, follow the above steps in reverse
order.
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......