BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.6
Problem
Cause
Solution
Replace the CPU board.
Pressing the “Enter” key does
not switch the status of the A
signals, and the motor solenoid
is not enabled.
The CPU board does not
produce the command signal.
Replace the keyboard.
Connector cable between the
CPU board and solenoid is
defective.
Replace the cable.
Bio servo board defective.
Replace the Bio servo board.
The solenoid does not change
status, even after receiving the
enable command.
Solenoid defective.
Replace the solenoid.