BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.191
7.5.20. D
ISASSEMBLING THE WEIGHT STACK SELECTION SYSTEM
Figure 7.5.20-1
Follow the steps described in paragraphs 7.5.11.
“Disassembling the upright guard” and 7.5.14.
“Disassembling the rear guard”.
1. Use a 17-gauge wrench to unscrew the 2
screws
a
.
2. Lift the rear pulley group.
Figure 7.5.20-2
3. Unscrew the 2 screws
b
using a 17-gauge
wrench.
4. Unscrew the screw
c
using a 4-gauge
hexagonal T-wrench.
5. Remove the transverse support plate
d
.
6. Disconnect the zero sensor cable.
Continued on next page
→