BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.31
Follow the step-by-step guide to properly diagnose the error. Pay special attention to those tests
indicated in numbered boxes, and described in detail here below:
(1)
Insert the multimeter probes between pins 1 (signal) and 2 on the CN27 patch cord. With the
brush far from the sensor you should get a reading of approximately 5 Vdc while with the
brush close to the sensor you should get a reading of approximately 0 Vdc.
(2)
Insert the multimeter probes between pins 1 (signal) and 2 on the CN4 connector on the Bio
servo board. With the brush far from the sensor you should get a reading of approximately 5
Vdc while with the brush close to the sensor you should get a reading of approximately 0 Vdc.
(3)
Insert the multimeter probes between pins 17 (signal) and 1 on the CN7 connector on the Bio
servo board. With the brush far from the sensor you should get a reading of approximately 5
Vdc while with the brush close to the sensor you should get a reading of approximately 0 Vdc.
(4)
Insert the multimeter probes between pins 3 (signal) of the K5 and 1 of the K4 connector on
the CPU board. With the brush far from the sensor you should get a reading of approximately
5 Vdc while with the brush close to the sensor you should get a reading of approximately 0
Vdc.
On Chest Press and Leg Press, the BS-6/2 cable is divided into 2 parts through the
connector CN36. Carry out the test on this connector and, if necessary, replace only the
defective section of the BS-6/2 cable.
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......