BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.394
7.9.44. D
ISASSEMBLING THE WEIGHT STACK CABLE
Figure 7.9.44-1
Follow the steps described in paragraph 7.9.8.
“Disassembling the plexiglas weight stack
guard”.
For each cam:
1. Unscrew the 2 dowels
a
, using a 4-gauge
hexagonal T-wrench.
2. Remove the cable with the aid of a pair of
pliers.
3. Remove the cable from the weight stack
pulleys.
To reassemble the WEIGHT STACK CABLE,
follow the above steps in reverse order.
When the operation is complete, adjust
the tension of the WEIGHT STACK
CABLE, and the phasing of the cam and
lever mechanism, as described in
paragraphs 8.4. and 8.2. .