7.9.36. D
ISASSEMBLING THE SHOULDER REST GROUP RELEASE CABLE
Figure 7.9.36-1
1. Shut off the equipment and unplug the power
cord from the wall socket.
2. Unscrew the setting screw of the LEVER
RELEASE CABLE, using a 13-gauge
wrench on the counter-nut
a
and screw
b
.
3. Pull the cable from the release handle,
passing the blocking ball through the holes
provided.
Figure 7.9.36-2
4. Unscrew the 3 screws
c
, using a 2.5-gauge
hexagonal T-wrench.
5. Use a 3-gauge hexagonal T-wrench to
unscrew the dowel
d
.
Continued on next page
→