BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.157
7.4.28. D
ISASSEMBLING THE WEIGHT STACK FRAME GUARD
Figure 7.4.28-1
Follow the steps described in paragraph 7.4.27.
“Disassembling the bell guard”.
1. Use a medium-sized Philips screwdriver to
unscrew the screw
a
.
2. Remove the UPPER GUARD.
Figure 7.4.28-2
3. Unscrew the 2 screws
b
using a 2.5-gauge
hexagonal T-wrench.
4. Remove the cross-piece
c
.
5. Remove the 4 caps
d
(2 on each side of the
GUARD) using a small flat screwdriver.
6. Use a medium-sized Philips screwdriver to
unscrew the 4 screws under the 4 caps
d
.
7. Widening the sides slightly, remove the
WEIGHT STACK FRAME GUARD by
sliding it down and then up.
To reassemble the WEIGHT STACK FRAME
GUARD, follow the above steps in reverse order.