BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 2.55
BS-6: Signal cable
CPU Board – Low Kit
Solenoid signal cable
CPU Board
K4
Signal
Color
SI board
CN1
17 Enable
White
2
15 Status
Green
3
12 Ground
Gray
4
Weight stack motor signal cable
CPU Board
K4
Signal
Color
WSMI board
CN1
3 Motor
up
Blue
2
5 Motor
down
Black
3
7 Alarm
Gray–pink
4
9 Pulses
White–green 5
1 Ground
White–yellow 6
Seat motor signal cable
CPU Board
K4
Signal
Color
SAMI board
CN1
4 Motor
up
Brown
2
6 Motor
down
Yellow
3
8 Alarm
Orange
4
10 Pulses
Red
5
2 Ground
Purple
6
FPGA signal cable
CPU Board
K3
Signal
Color
FPGA Board
CN2
3
Tx to CPU
White–Blue
4
6 Reset
White–brown 5
2 Ground
Shield
2
Zero sensor cable
CPU Board
K5
Signal
Color
Zero sensor
CN24
3
+ zero sensor
White–black
1
2
Zero sensor ground
White–gray
2
BS-00: Zero sensor extension cable
Patch – Patch
Patch
CN24
Signal
Color
Open
CN25
1 Signal
White
1
2 Ground
Black
2
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......