BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.45
6.17. THE DISPLAY DOES NOT TURN ON
This problem appears when the display does not receive enough supply voltage to initialize the CPU
board and manage the machine components. This is caused by a problem on the power supply line
regarding the following components: power cord, power entry, start button, fuses, filter, power
supply, Bio servo board, CPU board and the cables connecting them.
Check whether the fuses are
intact
Check whether the power
cord is intact
Check whether the power socket
of the fitness center where the
machine is installed supplies the
correct voltage
Replace the blown
fuses
Replace the power cord
Connect the machine to
another working socket
THE DISPLAY
DOES NOT TURN
ON
Check whether the line voltage
leaving the power entry is
correct
NO
YES
NO
YES
NO
YES
NO
YES
1
A
Replace the power
entry
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......