Page 7.343
7.8.40. D
ISASSEMBLING THE POWER ENTRY
Figure 7.8.40-1
1. Shut off the equipment and unplug the power
cord from the wall socket.
Follow the steps described in paragraph 7.8.16.
“Disassembling the mats” only for the left-hand
mat.
2. Unscrew the screw
a
using a 4-gauge
hexagonal T-wrench.
3. Remove the Plexiglas guard
b
.
The screw a remains inside the Plexiglas
guard.
4. Disconnect the 3 connector fastons
c
.
5. Remove the POWER ENTRY by pressing a
medium-sized straight screwdriver against its
plastic springs.
To reassemble the POWER ENTRY, follow the
above steps in reverse order