BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.38
6.15.2. F
OR
L
EG
E
XTENSION
, L
EG
C
URL
, V
ERTICAL
T
RACTION
, S
HOULDER
P
RESS
, C
HEST
P
RESS AND
R
OWING
T
ORSO
SEAT PROBLEM =
MOTOR
Replace the CPU board
Replace the BS-6/2
cable
Check whether the seat motor
enable output signal from the
CPU board is correct
NO
Check whether the seat motor
enable input signal to the Bio
servo board is correct
YES
2
3
Check whether the seat motor
enable output signal from the Bio
servo board is correct
NO
4
Replace the Bio servo
board
NO
Check whether the motor runs
NO
Replace the motor
YES
YES
YES
Replace the BS-2S
cable
Check whether the supply voltage
to the Bio servo board is correct
1
NO
A
YES
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......