BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.42
(3)
Insert the oscilloscope probes between pins 3 (signal) and 5 of the CN4 connector on the LP
driver board. With the motor enabled you should see a square wave signal ranging from
approximately 0 Vdc to 5 Vdc.
(4)
Insert the oscilloscope probes between pins 5 (signal) and 6 of the CN3 connector on the LP
driver board. With the motor enabled you should see a square wave signal ranging from
approximately 0 Vdc to 5 Vdc.
(5)
Insert the oscilloscope probes between pins 5 (signal) and 6 of the connector CN6 on the Bio
servo board. With the motor enabled you should see a square wave signal ranging from
approximately 0 Vdc to 5 Vdc.
(6)
Insert the oscilloscope probes between pins 10 (signal) and 2 of the connector CN7 on the Bio
servo board. With the motor enabled you should see a square wave signal ranging from
approximately 0 Vdc to 5 Vdc.
(7)
Insert the oscilloscope probes between pins 10 (signal) and 2 of the K4 connector on the CPU
board. With the motor enabled you should see a square wave signal ranging from
approximately 0 Vdc to 5 Vdc circa.
(8)
Insert the multimeter probes between pins 1 (signal) and 5 of the CN4 connector on the LP
driver board. You should get a reading of approximately 5 Vdc.
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......