BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.16
6.5. THE LCD DISPLAYS THE MESSAGE “HW FAULT: CHECK
BATTERY”
This error message appears when the machine finds incorrect data saved in the battery-powered
RAM of the buffer battery.
HW FAULT: CHECK
BATTERY
YES
Check whether the
buffer battery is
charged
Replace the buffer battery
NO
Replace the CPU board
1
Follow the step-by-step guide to properly diagnose the error. Pay special attention to those tests
indicated in numbered boxes, and described in detail here below:
(1)
Remove the buffer battery from the CPU board, and use a multimeter to measure the voltage
at its ends. It should read 3.6 Vdc.
The battery is recharged by the CPU board when powered. If the recharging part of the
board is not working, the battery will tend to run low over time.
After restoring the defective component, carry out the steps described in paragraphs 9.1.
“Configuring parameter defaults”, 9.2. “Configuring the technical parameters” and 9.3.
“Configuring the user parameters”.
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......