![Technogym BIOSTRENGTH LINE Скачать руководство пользователя страница 458](http://html1.mh-extra.com/html/technogym/biostrength-line/biostrength-line_service-maintenance-manual_1070169458.webp)
BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.284
7.7.28. D
ISASSEMBLING THE ELECTRICAL BOX
Figure 7.7.28-1
Follow the steps described in paragraph 7.7.17.
“Disassembling the upright guard”.
1. Unscrew the screw
a
using a 4-gauge
hexagonal T-wrench.
2. Open the cover of the ELECTRICAL BOX.
3. Disconnect the cable connectors
b
.
4. For each side, unscrew the 2 nuts
c
using a
10-gauge tube wrench.
5. Remove the ELECTRICAL BOX.
To reassemble the ELECTRICAL BOX, follow
the above steps in reverse order.