BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.386
7.9.37. D
ISASSEMBLING THE SHOULDER REST GROUP
Figure 7.9.37-1
1.
Position the SHOULDER REST
ADJUSTMENT at maximum height.
2. Follow the steps described in paragraph
7.9.36. “Disassembling the shoulder rest
group release cable”.
3. Use a medium-sized Philips screwdriver to
unscrew the 6 screws
a
.
4. Remove the 2 backrest guards.
Figure 7.9.37-2
5. Unscrew the 2 screws
b
using a 3-gauge
hexagonal T-wrench.
6. Remove the closing cover
c
.
7. Remove the cap
d
.
8. Use an 8-gauge T-wrench to unscrew the
screw
c
, holding the nut--accessible from
above--in place with a 17-gauge wrench.
9. Unscrew the 6 screws
a
using an 8-gauge
hexagonal T-wrench.
To unscrew the 2 bottom screws, you
must use a very short wrench.
10. Turn the backrest on the seat.
Continued on next page
→
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......