BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 2.62
Name Type of connector
Connection
CN35 4-pin open male AMP MODU II
Photocell signals
CN36 8x2-pin open male AMP MODU II
Signals from CPU to low kit
CN37 6-pin open male AMP MODU II
Signals from low kit to encoder and
solenoid
CN38 4-pin open MOLEX MINIFIT
Low-voltage FPGA-CPU power supply
CN39 2-pin open AMP MNL
LP seat motor power supply
2.6.4.2. Cables
BS-11: High-voltage power cable
Power socket – Power switch – Earth node
Power socket
CN11
Signal
Color
Power switch
CN13
PE
Faston Earth
Yellow–green -
Slot
Faston Neutral
Blue
Faston
-
Faston Phase
Black
Faston
-
BS-12: High-voltage power cable
Power switch – Fuses
Power switch
CN14
Signal
Color
Fuses
CN15
Faston Neutral
Blue
Faston
Faston Phase
Black
Faston
BS-13: High-voltage power cable
Fuses – Filter – Earth node
Fuses
CN16
Signal
Color
CN17
Filter
PE
Faston Neutral
Blue Faston -
Faston Phase
Black
Faston -
- Earth
Yellow–
green
Faston Slot
Содержание BIOSTRENGTH LINE
Страница 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Страница 2: ......
Страница 4: ......
Страница 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Страница 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Страница 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Страница 121: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 1 4 ACCESSORIES The equipment has no accessories...
Страница 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Страница 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Страница 645: ......