Analog-to-digital converters (ADC)
RM0351
584/1830
DocID024597 Rev 5
18.6.3
ADC control register (ADC_CR)
Address offset: 0x08
Reset value: 0x2000 0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
AD
CAL
ADCA
LDIF
DEEP
PWD
ADVREG
EN
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
rs
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
JAD
STP
AD
STP
JAD
START
AD
START
AD
DIS
AD
EN
rs
rs
rs
rs
rs
rs
Bit 31
ADCAL
: ADC calibration
This bit is set by software to start the calibration of the ADC. Program first the bit ADCALDIF to
determine if this calibration applies for single-ended or differential inputs mode.
It is cleared by hardware after calibration is complete.
0: Calibration complete
1: Write 1 to calibrate the ADC. Read at 1 means that a calibration in progress.
Note: Software is allowed to launch a calibration by setting ADCAL only when ADEN=0.
Note: Software is allowed to update the calibration factor by writing ADC_CALFACT only when
ADEN=1 and ADSTART=0 and JADSTART=0 (ADC enabled and no conversion is ongoing)
Bit 30
ADCALDIF
: Differential mode for calibration
This bit is set and cleared by software to configure the single-ended or differential inputs mode for
the calibration.
0: Writing ADCAL will launch a calibration in single-ended inputs mode.
1: Writing ADCAL will launch a calibration in differential inputs mode.
Note: Software is allowed to write this bit only when the ADC is disabled and is not calibrating
(ADCAL=0, JADSTART=0, JADSTP=0, ADSTART=0, ADSTP=0, ADDIS=0 and ADEN=0).
Bit 29
DEEPPWD
: Deep-power-down enable
This bit is set and cleared by software to put the ADC in Deep-power-down mode.
0: ADC not in Deep-power down
1: ADC in Deep-power-down (default reset state)
Note: Software is allowed to write this bit only when the ADC is disabled (ADCAL=0, JADSTART=0,
JADSTP=0, ADSTART=0, ADSTP=0, ADDIS=0 and ADEN=0).
Bit 28
ADVREGEN
: ADC voltage regulator enable
This bits is set by software to enable the ADC voltage regulator.
Before performing any operation such as launching a calibration or enabling the ADC, the ADC
voltage regulator must first be enabled and the software must wait for the regulator start-up time.
0: ADC Voltage regulator disabled
1: ADC Voltage regulator enabled.
For more details about the ADC voltage regulator enable and disable sequences, refer to
Section 18.4.6: ADC Deep-power-down mode (DEEPPWD) & ADC Voltage Regulator
(ADVREGEN)
.
The software can program this bit field only when the ADC is disabled (ADCAL=0, JADSTART=0,
ADSTART=0, ADSTP=0, ADDIS=0 and ADEN=0).
Bits 27:6 Reserved, must be kept at reset value.