DocID024597 Rev 5
189/1830
RM0351
Power control (PWR)
198
5.4.11
Power Port B pull-down control register (PWR_PDCRB)
Address offset: 0x2C.
Reset value: 0x0000 0000. This register is not reset when exiting Standby modes and with
PWRRST bit in the RCC_APB1RSTR1 register.
Access: Additional APB cycles are needed to access this register vs. a standard APB
access (3 for a write and 2 for a read).
5.4.12
Power Port C pull-up control register (PWR_PUCRC)
Address offset: 0x30.
Reset value: 0x0000 0000. This register is not reset when exiting Standby modes and with
PWRRST bit in the RCC_APB1RSTR1 register.
Access: Additional APB cycles are needed to access this register vs. a standard APB
access (3 for a write and 2 for a read).
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PU15
PU14
PU13
PU12
PU11
PU10
PU9
PU8
PU7
PU6
PU5
PU4
PU3
PU2
PU1
PU0
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Bits 31:16 Reserved, must be kept at reset value.
Bits 15:0
PUy
: Port B pull-up bit y (y=0..15)
When set, this bit activates the pull-up on PB[y] when APC bit is set in PWR_CR3 register.
The pull-up is not activated if the corresponding PDy bit is also set.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PD15
PD14
PD13
PD12
PD11
PD10
PD9
PD8
PD7
PD6
PD5
Res.
PD3
PD2
PD1
PD0
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Bits 31:16 Reserved, must be kept at reset value.
Bits 15:5
PDy
: Port B pull-down bit y (y=5..15)
When set, this bit activates the pull-down on PB[y] when APC bit is set in PWR_CR3 register.
Bit 4 Reserved, must be kept at reset value.
Bits 3:0
PDy
: Port B pull-down bit y (y=0..3)
When set, this bit activates the pull-down on PB[y] when APC bit is set in PWR_CR3 register.