Low-power universal asynchronous receiver transmitter (LPUART)
RM0351
1382/1830
DocID024597 Rev 5
Table 241. Error calculation for programmed baud rates at f
ck
= 32,768 KHz
Baud rate
f
CK
= 32,768 KHz
S.No
Desired
Actual
Value programmed in the baud
rate register
% Error = (Calculated - Desired)
B.rate / Desired B.rate
1
300 Bps
300 Bps
0x6D3A
0
2
600 Bps
600 Bps
0x369D
0
3
1200 Bps
1200.087 Bps
0x1B4E
0.007
4
2400 Bps
2400.17 Bps
0xDA7
0.007
5
4800 Bps
4801.72 Bps
0x6D3
0.035
6
9600 Bps
9608.94 Bps
0x369
0.093
Table 242. Error calculation for programmed baud rates at f
ck
= 80 MHz
Desired
Actual
Value programmed in the
baud rate register
% Error = (Calculated -
Desired)
B.rate / Desired B.rate
38400
38400,02
82355
0,00006
57600
57600,09
56CE3
0,0001
115200
115200,50
2B671
0,0004
230400
230402,30
15B38
0,001
460800
460804,61
AD9C
0,001
921600
921609,22
56CE
0,001
4000000
4000000,00
1400
0
10000000
10000000,00
800
0
20000000
20000000,00
400
0
26000000
26022871,66
313
0,09