The ROUTE Module
Viewing Time Waveform Data
Y-Axis Graph Scaling Adjustment
– Use the up/down arrow buttons to manually
adjust the y-axis graph scaling on the spectrum. This allows you to re-scale the plot to
get a closer look at low amplitude components.
Up arrow button – D
ecreases the Y
-axis graph scale setting by ½ of its current
setting.
Down arrow button –
Doubles the Y
-axis graph scale setting.
Harmonic Markers – “H” key
–
In a spectral display, press the “H” alphanumeric
key to
display harmonic markers for the current cursor position. Use harmonic markers to
rapidly locate integral orders in relation to their fundamental (1X). The
H
key cycles the
three harmonic cursor modes:
Simple
,
Harmonic
, and
Fixed
.
Simple
–
No har
monic cursors.
Harmonic
–
Harmonics of the current cursor position are displayed. The
spectral cursor acts as the fundamental marker, and is re-positioned using the
left/right arrow buttons.
Fixed
–
Harmonics remain fixed, and cursor can be moved indepe
ndently.
The default is
Simple
(off).
Peak Cursor
–
“P” key
– In a spectral display, press the “P” alphanumeric key to quickly
jump the cursor to the next highest peak to the right of the cursor.
Display Expansion - +/- ke
y – This function graphically expands or compresses the
frequency domain display range horizontally around the cursor position to use the full
dynamic range of the Microlog. It reveals characteristics that may be hidden by the
display mode or by the resolution without changing data collection parameters.
•
With a spectrum displayed, press the keypad’s
+/-
key. The spectrum’s fmax
setting expands and the spectrum reforms to the new fmax. Repeat to continue to
expand up to the maximum resolution (based on the number of lines of resolution
for the spectrum), after which the function switches to compression.
Dot (.) key
– Immediately toggles the
+/-
key between display
expansion and compression.
Viewing Time Waveform Data
Time waveform plots display a short time sample of a raw vibration signal with vibration
amplitude plotted over the time scale. Time waveform data displays on a plot similar to
the spectrum display screen.
3 - 14
SKF Microlog - GX Series
User Manual