Machinery Balancing Module
How to Perform a Dynamic 2 Plane Procedure
Figure 5 - 23.
The 2-Plane Initial Run Polar Plots Showing Plane A and Plane B Data.
Use the Right / Left Arrow Buttons to Move
between the Plots.
Important
-
Note the speed reading above the prompt line. For accurate balancing
results, it is important to maintain the same speed across all balancing runs.
Bar
–
When selected, the
Polar
function button changes to a
Bar
function button. Push
the
Bar
function button to view the run data in bar chart format.
From here you have two options to record the measurement; you may use either the
Average
function button or the
Stop
function button. Both are described in the
preceding
How to Perform a Single-Plane Procedure
section.
•
Press either the
Average
or
Stop
function button to record the measurement.
It is recommended that you save the initial run so that you do not
have to repeat it. Then you can update the saved file with
subsequent runs.
•
To proceed with the balancing job, follow the on-screen prompt and press an
Enter
/ Fire key to proceed to enter Trial Weight data.
5 - 30
SKF Microlog - GX Series