Introduction to the SKF GX Series Microlog
GX Series Microlog Specifications
Preprocessing
•
Enveloper (demodulator): With four selectable input filters fo
r enhanced bearing
and gear mesh fault detection
•
Filter selection:
–
5 Hz to 100 Hz
–
50 Hz to 1 kHz
–
500 Hz to 10 kHz
–
5 kHz to 40 kHz
•
Input parameters:
–
Tachometer: TTL / analogue programmable to ±
25 V
–
RPM range 1 to 99 999
–
Tachometer power supply 5 V at 100 mA
•
Input over-voltage protection:
–
AC ±50 V peak
–
DC ±50 V sustained
•
Dynamic range: >90 dB (24 bit ADC sigma-delta)
•
Input connectors:
–
CH1: Six pin Fischer, CH1, CH2, CH3
–
CH2: Six pin Fischer, CH2, CH3
–
USB host / CHR / headphone: USB keyboard, CHR, head
phones
–
USB Device / power / trigger: Seven pin Fischer trigger in, trigger tachometer
power supply, USB COMMS, charger
•
Input signal range: ±25 V maximum
Data processing and storage
•
Microprocessor: Marvell 806 MHz PXA320
•
Internal storage: 128 MB (capable of storing approximately 4 000 spectra)
•
SD card: SD memory card up to 16 GB
Measurement
•
Range:
–
Route measurements: DC to 8
0 kHz
–
Analyzer measurements: DC to 8
0 kHz
•
Averaging: 1 to 255 time averages, 1 to 4 096 spectral averages
•
Averaging type: RMS, Exponential
, Peak Hold, and Time Sync
•
Cursor: Fixed and cursor lock. Single, harmonic and peak pick.
•
Trigger modes: Free run or external trigger (trigger slope and amplitude)
•
Resolution: Programmable 100, 200, 400, 800, 1 600, 3 200, 6 400, 12 800, and
25 600 lines
•
Measurement windows: Hanning,
Flattop and Uniform
1 - 30
SKF Microlog - GX Series
User Manual