Machinery Balancing Module
How to Perform
a 1-2 Plane with Prognosis Procedure
Figure 5 - 33.
The 2-Plane Initial Run Screen with Data Displayed.
The measurement results continuously update on the screen. This allows you to
determine how stable the measurement conditions are, prior to recording the
measurement.
The
Polar
,
Average
,
Stop
,
Table,
and the shifted
Save
function buttons all operate as
previously described in the
How to Perform a Dynamic 2 Plane Balancing Procedure
section.
•
Press either the
Average
or
Stop
function button to record the measurement.
It is recommended that you save the initial run so that you do not
have to repeat it. Then you can update the saved file with
subsequent runs.
•
To proceed with the balancing job, follow the on-screen prompt and press an
Enter
/ Fire key to proceed to enter Trial Weight data.
5 - 40
SKF Microlog - GX Series
User Manual