![SKF Microlog GX Series Скачать руководство пользователя страница 149](http://html1.mh-extra.com/html/skf/microlog-gx-series/microlog-gx-series_user-manual_1287103149.webp)
Machinery Balancing Module
How to Perform a Single
-Plane Procedure
The
Correction Weight
screen displays the permanent
Corr
ection
weight
,
Angle
, and
Radius
balance solution at the top of the screen, and correction weight options at the
bottom.
•
Stop the machine
, remove the temporary trial weight (if appropriate), and securely
attach the permanent correction weight at the precise angle and radius specified.
Split Weight
- Sometimes a weight cannot conveniently be placed at the angle
specified by balancing computations. The
Split Weight
option automatically splits the
specified weight into two weights positioned at two placement angles around the
original angle.
Add/Remove
– Specify whether you are adding or subtracting the correction weight.
Corr Weight
and
Angle
settings automatically adjust per your selection. Defaults to
Add
.
Correction
– (
Polar
or
Component
), allows you to change the
Correction Type
setting,
if required (e.g., if you were using
Correction Type / Polar
but now discover that you
cannot place the weights where necessary, you can change to
Correction Type /
Component
). If you change from
Correction Type /Polar
to
/ Component
, you will be
prompted to enter the number of components, after which the
Actual Correction
dialog
will indicate each weight and at which angle to place each weight.
Combine All
– Press to have the Microlog combine all the weights being used into one
weight. You will be prompted to confirm the process, after which the
Actual Correction
dialog will indicate the combined weight and at which angle to place the combined
weight.
Actual
– If you do not have the exact correction weight indicated in the
Corr Weight
field, press the
Actual
function button, the
Actual Correction
dialog displays and allows
you to enter the actual correction weight and angle you are using.
Figure 5 - 16.
The
Actual Correction
Dialog.
SKF Microlog - GX Series
5 - 21
User Manual