Machinery Balancing Module
How to Perform a Dynamic 2 Plane Procedure
Perform the Trial Run for Plane B
•
With the trial weight securely attached to the machine,
start the machine
and bring
it back up to the same speed used with the reference run (initial run).
•
Press an Enter / Fire button. Plane B’s Trial Run
screen displays.
Figure 5 - 27.
Plane B’s Trial Run Screen (Polar Version).
Plane B’s trial weight also affects plane A. If desired, use the left /
right arrow keys to view the polar plot for the other plane so that
you can observe how the trial weight affected it.
From the Plane B’s Trial Run screen, after
Stop
ping data collection, press an Enter /
Fire button to proceed to enter the correction weight. Before doing so, you are
prompted whether the trial weight for plane B will be removed, answer appropriately.
The
Balancer – Correction Weight
screen displays.
5 - 34