3 sets of Rubber Gasket Insert are provided for different cable diameters:
4.2mm inner diameter – for cable diameter 3.5-4.9mm
5.8mm inner diameter – for cable diameter 5.0-6.7mm
7.9mm inner diameter – for cable diameter 6.8-9.0mm
1.
For each ODU cable connection, perform the following procedure:
a.
Disassemble a protective shell by unscrewing its parts and carefully
removing the Rubber Gasket Insert (
) from the Cable Inlet Portion (
) of
the shell.
b.
Thread the cable connector through the Cable Inlet Portion (
)of the shell,
through the Rubber Gasket Insert (
) and through the Connector Outlet
Portion (
) as shown in
Figure
2-5
.
c.
Connect the cable connector to the ODU interface.
d.
Screw the Connector Outlet Portion (
) to the ODU firmly by hand (do not
use tools).
e.
Insert the Rubber Gasket Insert snugly into the Connector Outlet Portion (
)
of the shell.
f.
Screw the Cable Inlet Portion (
) to the Connector Outlet Portion (
)firmly
by hand (do not use tools).
2.7.4
Removing Connectors from the EtherHaul ODU
Caution:
To avoid accidental damage to the connector, always use the following order to
remove cable connections from the ODU (refer to
Figure
2-5
).
1.
Unscrew the Cable Inlet Portion (
) of the All-Weather Shell first to release the
gasket seal and remove tension from the cable connector.
2.
Unscrew the Connector Outlet Portion (
) of the All-Weather Shell from its
ODU port.
3.
Remove the cable connector from its port.
2.7.5
Connecting the Power
1.
Carefully screw the Connector Outlet Portion (
)
of the All-Weather Shell into
the PWR port or alternatively, if a PoE connection is being used, the RJ1 port.
Tighten the Connector Outlet Portion securely by hand.
Do not use a wrench
.
2.
Insert the power or PoE data connector into the port. The PWR LED color
indicator will turn red for one second, then blinking green. This indicates that
the ODU is powered on.
3.
Screw the Cable Inlet Portion (
)
of the All-Weather Shell onto the secured
Connector Outlet Portion, taking care not to twist the connecting cable. Tighten