Installation and User Manual
EtherHaul
1200™
Page 192
EH-INST-02, Issue 4.0
11.9
Radio Object Attributes
11.9.1 RF Object Attributes
This section lists configurable RF attributes (Table
11-3) and read-only RF attributes
(Table
11-5) separately.
Table
11-3 Configurable RF Attributes
Attribute (CLI
Attribute Name)
Description
SNMP Object ID
Value
Default
Number of
Channels (num-
of-channels)
The maximum allowed
bandwidth, expressed in MHz.
rfNumOfChannels
(1.3.6.1.4.1.31926.2.1.1.
2)
1..2
2
Operational
Frequency
(frequency)
The frequency at which the RF
operates, expressed in MHz.
rfOperationalFrequency
(1.3.6.1.4.1.31926.2.1.1.
4)
50000..80000
74000
Role (role)
The current role of the RF
device.
rfRole
(1.3.6.1.4.1.31926.2.1.1.
5)
master, slave
master
Mode Selector
(mode)
The current RF device operating
mode.
When static mode is specified,
only certain sub-parameter
combinations will produce a
valid result. When an invalid
combination is specified on the
command line, the CLI will
respond with: “the modulation
does not exist in the modulation
table.”
rfModeSelector
(1.3.6.1.4.1.31926.2.1.1.
6)
adaptive, static, alignment
When static mode is
specified, additional sub-
parameters are used to
define additional relevant
operating characteristics,
as shown in Table
11-4.
adaptive
CINR Low (cinr-
low)
The lowest acceptable value for
CINR, expressed in decibels
(dB).
rfCinrLow
(1.3.6.1.4.1.31926.2.1.1.
13)
-128..127
0
CINR Interval
(cinr-interval)
The interval used to determine
the value for CINR, expressed in
milliseconds.
rfCinrInterval
(1.3.6.1.4.1.31926.2.1.1.
15)
0..2000
0
RSSI Interval
(rssi-interval)
The interval used to determine
the value for RSSI, expressed in
milliseconds.
rfRssiInterval(1.3.6.1.4.1
.31926.2.1.1.16)
0..2000
0
RX Link ID (rx-
link-id)
The RF receive link ID.
rfRxLinkId
(1.3.6.1.4.1.31926.2.1.1.
22)
Varies
0
TX Link ID (tx-
link-id)
The RF transmit link ID.
rfTxLinkId
(1.3.6.1.4.1.31926.2.1.1.
23)
Varies
0
Transmit
Asymmetry (tx-
asymmetry)
Percentage of the TX part in the
airframe.
integer. CLI syntax is
{10tx-90rx |25tx-75rx |
50tx-50rx | 75tx-25rx |
90tx-10rx}.
50tx-