Relative Humidity – 0 to 100%
Maximum Altitude – 4,500m
Ingress Protection Rating – IP67
2.1.2
Cabling Requirements
Ensure that your power connection cable matches the EtherHaul power
connector pin-outs. See
Figure
2-3
for the DC power connector pin-out
diagram.
Install the EtherHaul ODU where network connections and optional power
cabling are ready for operation and easily accessible.
All cabling connected to the ODU should be outdoor-grade, with UV
protection.
Use a 2-wire cable (14-18 AWG) to connect the power supply to the ODU.
Outdoor Cat5e cables terminated with RJ45 connectors should be used.
Shielded cables and connectors should be used.
In order to protect indoor equipment, surge protection circuits must be
installed on all copper cables (DC and Ethernet) on their entrance to the
building.
Install the EtherHaul ODU in a location where proper electrical outdoor
grounding is readily available. Typically, the grounding connection is
attached directly to the mounting pole. If not already present, then suitable
structure-to-earth grounding connections must be created before
installation. Ground the ODU using a minimum quantity of 16AWG
grounding cable or according to local electrical code.
Note:
Improper electrical grounding can result in excessive electromagnetic interference or
electrical discharge.
Siklu will not be held responsible for any malfunction or damage in the event that the
ODU is not properly grounded.