Functions
5.8 Direct data exchange
PROFINET with STEP 7
Function Manual, 05/2021, A5E03444486-AL
239
4.
Create a new transfer area by double-clicking on "<Add new>". Assign a meaningful name
for the transfer area.
A transfer area for direct data exchange between the sender and receiver 1 is configured.
Figure 5-86 Transfer area for direct data exchange
5.
Now, select the PROFINET interface of a receiver for which a transfer area is not yet set up,
e.g. receiver 2.
6.
Change to the table view of the network view to "I/O communication"
The communication relation for direct data exchange with the sender is displayed.
Figure 5-87 Connection for direct data exchange in receiver 2
7.
Select the communication relation.
8.
Navigate to the properties to "General" > "Direct data exchange" > "Transfer areas".
9.
Create a new transfer area by double-clicking on "<Add new>". Assign a meaningful name
for the transfer area.
A transfer area for direct data exchange is configured.