OPC UA communication
9.3 Using the S7-1500 as an OPC UA server
Communication
250
Function Manual, 05/2021, A5E03735815-AJ
12.
Click "OK".
SiOME shows the new instance "IMM_Manufacturer_01234" in the "Information model"
area under "DeviceSet":
Figure 9-29 Display information model
13.
Create an instance of the data type "InjectionUnitType".
To do this, right-click on the "InjectionUnits" directory in the "Information model" area and
select "Add Instance".
SiOME displays the "Add Instance" dialog.
For "Name", enter a meaningful name for the instance.
In the example, enter "InjectionUnit_1".
For "TypeDefinition", select "InjectionUnitType".
Click "OK".
14.
Create a new "Mould_1" instance of the "MouldType" object type in the "Moulds" directory.
15.
Create a new instance "PowerUnit_1" of the "PowerUnitType" object type in the "PowerUnits"
directory.
16.
Save the XML file.
To do so, click the "Quick save" button in the "Information model" area:
Figure 9-30 "Quick save" button in SiOME