Digital input/Digital output module DIQ 16x24VDC/0.5A 8xM12 (6ES7143-5AH00-0BA0)
56
Equipment Manual, 08/2021, A5E38688112-AD
4.2.2
Parameters/address space
4.2.2.1
Parameters
In the configuration method 4xCount of the digital input / digital output module
DIQ 16x24VDC/0.5A 8xM12 the Channels 0 to 7 are used by the counting function. The
Channels 8 to 15 can be parameterized freely.
The following table shows the general parameter of the module.
Table 4- 21 General parameters
Parameters
Value range
Default
Scope
Diagnostics: Missing load voltage
2L+
•
Disable
•
Enable
Disable
Module
Diagnostics: Short-circuit to
ground
•
Disable
•
Enable
Disable
Module
(Short-circuit of the
encoder supply or
of the output to
ground)
Behavior at CPU/master STOP
(8...15)
•
Shut down
•
Keep last value
•
Output substitute
value
Shut down
Module
(digital outputs)
The table below shows the parameters of Counter 0 to Counter 3.
Table 4- 22 Parameters of Counter 0 to Counter 3
Parameter
Value range
Default
Scope
Counting behavior Counter 0 (DI0), Counter 1 (DI2), Counter 2 (DI4) and Counter 3 (DI6)
Input delay DI
•
0.05 ms
•
0.1 ms
•
0.4 ms
•
0.8 ms
•
1.6 ms
•
3.2 ms
•
12.8 ms
•
20 ms
0.05 ms
Counter
Counting direction
•
Forward
•
Backward
Forward
Counter
Edge selection
•
On a rising edge
•
On a falling edge
On a rising edge Counter
Содержание SIMATIC ET 200AL
Страница 2: ......
Страница 143: ......
Страница 218: ......
Страница 250: ......
Страница 296: ......
Страница 337: ......
Страница 365: ......
Страница 392: ......
Страница 419: ......
Страница 451: ......
Страница 483: ......
Страница 597: ......
Страница 648: ......
Страница 702: ......
Страница 739: ......
Страница 781: ......
Страница 804: ......
Страница 828: ......
Страница 853: ......
Страница 880: ......
Страница 906: ......
Страница 996: ...Diagnostics ...
Страница 1121: ......
Страница 1565: ......