4.2.7
Seam program parameters in cycles
Display windows
Program N
°
0
Electrodes
1
(1-4)
Current
NO
(NO,YES)
Working Mode
D‰
Limits Check
NO
(NO,YES)
Pressure 0
0
(0-99%)
Squeeze SV
NO
(NO,EV1-EV4)
Squeeze
0
(0-199)
Motor NO (NO,EV1-EV4)
Delay Weld Time
0.0
(0.0-99.0)
Slope up Initial Curr.
0
(0-50%)
Slope Up
0
(0-10)
Pressure 1
0
(0-99%)
Weld time 1
0.5
(0.5-99.0)
Cold time 1
0.0
(0.0-99.0)
Weld Current 1
100
(100-99‰)
(D‰,V‰)
Weld Current 1
1.0
(1.0-ImaxKA)
(IK)
Pressure 2
0
(0-99%)
Weld time 2
0.5
(0.5-99.0)
Cold time 2
0.0
(0.0-99.0)
Weld Current 2
100
(100-999‰)
(D‰,V‰)
Weld Current 2
1.0
(1.0-ImaxKA)
(IK)
Pressure 3
0
(0-99%)
Weld Time 3
0.5
0.5-99.0)
Cold time 3
0.0
(0.0-99.0)
Weld Current 3
100
(100-999‰)
(D‰,V‰)
Weld Current 3
1.0
(1.0-ImaxKA)
(IK)
Slope Dw
0
(0-10)
Slope DW Final Curr.
0
(0-50%)
Hold time
0.5
(0.5-99.0)
Off time
0.0
(0.0-99.0)
Initial Blanking
0.5
(0.5-10)
Curr. Max. Limit
1.0
(1.0-ImaxKA)
(D‰,V‰)
Curr. Min. Limit
1.0
(1.0-ImaxKA)
(D‰,V‰)
Curr. Max. Limit
1
(1-30%)
(IK)
Curr. Min. Limit
1
(1-30%)
(IK)
EXIT (Press +)